7 research outputs found

    Increased Risk of Non-Q Wave Myocardial Infarction After Directional Atherectomy Is Platelet Dependent: Evidence From the EPIC Trial

    Get PDF
    AbstractObjectives. We sought to determine the effects of platelet glycoprotein IIb/IIIa receptor blockade on adverse outcomes, especially non-Q wave myocardial infarction, in patients undergoing directional atherectomy in the Evaluation of c7E3 for the Prevention of Ischemic Complications (EPIC) trial.Background. Randomized trials comparing directional atherectomy with percutaneous transluminal coronary angioplasty (PTCA) have demonstrated modest benefits favoring atherectomy but at a cost of increased acute ischemic complications, notably non-Q wave myocardial infarction. The mechanism for this excess risk is unknown.Methods. Of 2,038 high risk patients undergoing coronary intervention in the EPIC trial, directional atherectomy was performed in 197 (10%). Patients randomly received the chimeric glycoprotein IIb/IIIa antibody 7E3 (c7E3), as a bolus or a bolus and 12-h infusion or placebo. Study end points included death, myocardial infarction, repeat intervention or bypass surgery.Results. Patients undergoing directional atherectomy had a lower baseline risk for acute complications but had a higher incidence of any myocardial infarction (10.7% vs. 6.3%, p = 0.021) and non-Q wave myocardial infarction (9.6% vs. 4.9%, p = 0.006). Bolus and infusion of c7E3 reduced non-Q wave myocardial infarctions by 71% after atherectomy (15.4% for placebo vs. 4.5% for bolus and infusion, p = 0.046). Non-Q wave myocardial infarction rates after PTCA were not affected by c7E3, although Q wave myocardial infarctions were reduced from 2.6% to 0.8% (p = 0.017).Conclusions. The EPIC trial confirmed the increased risk of non-Q wave myocardial infarction with directional atherectomy use compared with PTCA. A bolus and 12-h infusion of the glycoprotein IIb/IIIa receptor inhibitor c7E3 abolished this excess risk. Directional atherectomy-related non-Q wave myocardial infarction appears to be platelet aggregation dependent

    Steps toward determination of the size and structure of the broad-line region in active galactic nuclei. 5: Variability of the ultraviolet continuum and emission lines of NGC 3783

    Get PDF
    We report on the results of intensive ultraviolet spectral monitoring of the Seyfert 1 galaxy NGC 3783. The nucleus of NGC 3783 was observed with the International Ultraviolet Explorer satellite on a regular basis for a total of 7 months, once every 4 days for the first 172 days and once every other day for the final 50 days. Significant variability was observed in both continuum and emission-line fluxes. The light curves for the continuum fluxes exhibited two well-defined local minima or 'dips,' the first lasting is less than or approximately 20 days and the second is less than or approximately 4 days, with additional episodes of relatively rapid flickering of approximately the same amplitude. As in the case of NGC 5548 (the only other Seyfert galaxy that has been the subject of such an intensive, sustained monitoring effort), the largest continuum variations were seen at the shortest wavelengths, so that the continuum became 'harder' when brighter. The variations in the continuum occurred simultaneously at all wavelengths (delta(t) is less than 2 days). Generally, the amplitude of variability of the emission lines was lower than (or comparable to) that of the continuum. Apart from Mg II (which varied little) and N V (which is relatively weak and badly blended with Ly(alpha), the light curves of the emission lines are very similar to the continuum light curves, in each case with a small systematic delay or 'lag.' As for NGC 5548, the highest ionization lines seem to respond with shorter lags than the lower ionization lines. The lags found for NGC 3783 are considerably shorter than those obtained for NGC 5548, with values of (formally) approximately 0 days for He II + O III), and approximately 4 days for Ly(alpha) and C IV. The data further suggest lags of approximately 4 days for Si IV + O IV) and 8-30 days for Si III + C III). Mg II lagged the 1460 A continuum by approximately 9 days, although this result depends on the method of measuring the line flux and may in fact be due to variability of the underlying Fe II lines. Correlation analysis further shows that the power density spectrum contains substantial unresolved power over timescales of is less than or approximately 2 days, and that the character of the continuum variability may change with time

    Primary Pulmonary Responses to Toxic Agents

    No full text

    Track Reconstruction with Cosmic Ray Data at the Tracker Integration Facility

    No full text
    The subsystems of the CMS silicon strip tracker were integrated and commissioned at the Tracker Integration Facility (TIF) in the period from November 2006 to July 2007. As part of the commissioning, large samples of cosmic ray data were recorded under various running conditions in the absence of a magnetic field. Cosmic rays detected by scintillation counters were used to trigger the readout of up to 15\,\% of the final silicon strip detector, and over 4.7~million events were recorded. This document describes the cosmic track reconstruction and presents results on the performance of track and hit reconstruction as from dedicated analyses

    SLAVERY: ANNUAL BIBLIOGRAPHICAL SUPPLEMENT (2005)

    No full text
    corecore